Chapter 9 Ignition Systems Chapter 9—Ignition Systems 9-7 primary intermittent ignition (the spark is on whenever the motor is on). For interrupted ignition, you need a primary control built for this purpose. Attach one wire from the transformer or ignitor to the neutral wire and the other wire to the ignition wire or terminal on the primary control. See Figure 9-5 for wiring a primary control interrupted ignition (the spark shuts off once flame is established). Figure 9-4: Wiring a primary intermittent igntion Figure 9-5: Wiring a primary control interrupted ignition Control Switch Toggle Switch Stair Switch Thermostat Cad Cell Cad Cell Relay Primary Control High Limit Switch Low Water Cutoff Black White Orange Ignition Transformer Burner Motor Fuse Legend: Screw Terminal ¼" Quick Connect Terminal Power Supply, Provide Disconnect Means and Overload Protection as Required Optional Feature on Selected Models Refer to Device Label for Wire Color Code Valve is Optional on Specific Models See Figure 2 Thermostat To Remote Alarm Circuit Cad Cell Junction Box Jumper